Sharp Solar Inverter
Sharp Solar Inverter


Sharp is a household name for most electrical appliances. But for Sharp Solar Inverter the company have outsourced warranty claims and have little support for inverters out of warranty. ACE have been able to help with warranty claims and organise replacement parts from them but it is a difficult process that needs to be followed.
Trouble Shooting Tips
Below is a list of error and fault readings to help you better understand your solar inverter and aid the quick fix of a fault related to your Sharp JH1600 inverter:
| Fault Readings – F: Caused By Power From the Grid | ||
|---|---|---|
| Reading | Description | |
| F – 00 | Utility over-voltage | |
| F – 01 | Utility under-voltage | |
| F – 02 | Utility over frequency | |
| F – 03 | Utility under frequency | |
| F – 06 | Frequency over | |
| F – 07 | Frequency under | |
| Solar1 High | Modify the solar array setting and make the Voc less than 1000 Vdc | |
| F – 08 | Utility lock signal | |
| F – 09 | Frequency abnormality | |
| Fault Readings – P: Caused By Voltage Coming From Solar Panels | ||
| P – 11 | Solar panel voltage over 320 Volts | |


Below are some suggested solutions for your SharpJH1600 Solar Inverter Error and Fault Readings problems:
- Plugs and cables are connected, especially to the AC isolate and solar supply main switch on the switchboard
- Turn off the inverter AC isolator, located in the main switch supply
- Turn off the DC isolator, located on the inverter itself
- Wait for 1 minute
- Turn back on the AC isolator, followed by the DC isolator
- Wait 3 minutes until inverter restarts
Please note that these are general tips only and are based on our current and past experience and therefore, not specific to your solar inverter problem. What we usually find is people trying these troubleshooting tips and if these fail, they give us a call and we can perform diagnostic tests.What we usually find is people trying these troubleshooting tips and if these fail, they give us a call and we can perform diagnostic tests and provide a solution

50% of the time it’s a quick easy fix for any solar tech…
Other 50% of the time

A little knowledge of your solar system will help to you keep safe – watch our easy to follow video on Solar System Circuit Breaker DC Isolators.
Click here to find out exactly how ACE can assist with your solar system.